Star-water-systems CF511 (Flint & Walling) User Manual

Browse online or download User Manual for Pumps Star-water-systems CF511 (Flint & Walling). Star Water Systems CF511 (Flint & Walling) User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
© 2011. All rights reserved.
ATTENTION: READ CAREFULLY BEFORE ATTEMPTING TO INSTALL OR OPERATE YOUR PUMP. PROTECT YOURSELF AND OTHERS BY
OBSERVING ALL SAFETY INFORMATION AND ADDITIONAL INSTRUCTIONS INCLUDED WITH EQUIPMENT. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN FOR FUTURE REFERENCE.
FW0393
0611
Supersedes
0909
INSTALLATION INSTRUCTIONS
These installation instructions are applicable for Models CS511,
CF511 and C511 Portable Utility Pumps
Notice to Installer: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO: 95 North Oak Street • Kendallville, IN 46755
(260) 347-1600 • 1 (800) 345-9422 • FAX (260) 347-0909
1. Make certain that the power source conforms to the requirements of
the equipment as stated on the product nameplates.
2. Check hoses for weak or worn conditions before use and make certain
that all connections are secure.
3. Periodically inspect the pump for damage and perform routine
maintenance as required.
4. The maximum temperature of the pumped liquid must not exceed
120° F. The minimum allowable temperature is 40° F.
5. Use a screen or strainer on the inlet to prevent solids from entering
the pump.
6. To avoid internal pump damage, pump should not be run for more than
five minutes while attempting to prime.
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
SEE BELOW FOR LIST OF WARNINGS
SEE BELOW FOR LIST OF CAUTIONS
Quality Products Since 1866
PumpMate
®
Portable Utility Pump
1.
Make sure that the pump is plugged into a properly
grounded electrical receptacle. Use an Underwriters Labo-
ratory listed circuit analyzer to test for proper installation of
the circuit and ground. Any service to circuits or receptacles
should be conducted by a qualified licensed
electrician.
2.
Do not remove the ground pin from the plug under any
circumstances. If the ground pin is damaged, replace the
power cord or plug before use.
3.
All electrical installations must conform to the requirements of
the National Electric Code and all local codes.
4.
It is strongly recommended that the unit (Model CS511, CF511
or C511) be plugged into a GFI protected circuit.
5.
Disconnect power before servicing the pump or motor by
unplugging the unit from the outlet.
6.
Do not touch the motor when operating and allow the motor
to cool before touching it afterwards.
7. This pump is designed for water only. It has not been evaluated for pump-
ing of chemicals.
8.
Do not use this product to pump flammable or explosive
liquids.
9.
Do not use this product in hazardous environments or any-
where a spark could potentially ignite explosive gases.
10.
Do not handle this product with wet hands or while standing in
water or on a wet or damp surface.
11. Models CS511, CF511 and C511 are supplied with an automatically
resetting thermal overload device and can restart without warning.
12.
Do not submerge the pump or motor in water.
13. Secure the discharge line before starting the pump. An unsecured
hose can whip, possibly causing personal injury or property damage.
14.
Provide a means of pressure relief if the pump dis-
charge can be shut off or obstructed. Pumps operat-
ing against a closed discharge can create very hot
pumped liquid, which can cause burns.
15. Do not operate this product while unattended.
16.
Product is portable, and not intended to be permanently
installed outdoors. If installed outdoors, care should be
taken to protect the unit from rain and other elements of the
weather.
17. According to the state of California (Prop 65), this product contains
chemicals known to the state of California to cause cancer and birth
defects or other reproductive harm.
IL0387
Pump must be lled with water
before running.
IN
OUT
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Portable Utility Pump

1© 2011. All rights reserved.ATTENTION: READ CAREFULLY BEFORE ATTEMPTING TO INSTALL OR OPERATE YOUR PUMP. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL

Page 2 - MAINTENANCE

2© 2011. Tous droits réservés.DESCRIPTIONCette pompe utilitaire portable est conçue pour être utilisée comme pompe de transfert dans des applications

Page 3 - PERFORMANCE

3© 2011. Tous droits réservés.1. La pompe devrait être vérifiée régulièrement pour assurer un bon fonctionnement. Débranchez toujours l’alimentation

Page 4 - LIMITED WARRANTY

4© 2011. Tous droits réservés.Ce produit est garanti pendant la période expirant la première, un an après la date d’achat ou deux ans après la date de

Page 5

2© 2011. All rights reserved.DESCRIPTIONThis portable utility pump is designed to be used as a transfer pump for such applications as emptying water h

Page 6 - MANTENIMIENTO

3© 2011. All rights reserved.Brush Replacement Brushes for this pump should be inspected after every 100 hours of operation.Pumps with excess of 100

Page 7 - ESPECIFICACIONES

4© 2011. All rights reserved.This product is warranted for one year from the date of purchase or two years from the date of manufacture, whichever occ

Page 8 - GARANTÍA LIMITADA

1© 2011. Reservados todos los derechos.ATENCIÓN: LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR O UTILIZAR LA BOMBA. PROTÉJASE Y PROTEJA A L

Page 9

2© 2011. Reservados todos los derechos.DESCRIPCIÓNLa bomba portátil de uso general ha sido diseñada para usarse como bomba de transferencia en aplicac

Page 10 - ENTRETIEN

3© 2011. Reservados todos los derechos.Rendimiento Model CF5110 20 40 60 80 100 120 0 5 10 15 20 25 30Flow - GPMTotal Dynamic Head - Ft. IL0153 S

Page 11 - SPÉCIFICATIONS

4© 2011. Reservados todos los derechos.La garantía de este producto expirará después de transcurrido el más corto de los siguientes lapsos: un año con

Page 12 - GARANTIE LIMITÉE

1© 2011. Tous droits réservés.ATTENTION : LIRE ATTENTIVEMENT LA NOTICE AVANT D’INSTALLER OU DE FAIRE FONCTIONNER LA POMPE. SE PROTÉGER, AINSI QU’AUTR

Comments to this Manuals